Bags are not sold by R-value — they are sold by the coverage chart on the bag. This works backwards from the R you want to the bags and the depth it settles to.
R-38 over 1,000 sq ft, cellulose
Where the bag numbers come from
A 25 lb bag of cellulose is not "one bag per 40 sq ft". The manufacturer publishes a coverage chart: at R-30 one bag covers about 30 sq ft, at R-19 about 54 sq ft. Both numbers are on the same bag, and both are correct — the depth is what changes.
We interpolate between the published points and warn past the last one. If your target is R-49 and the chart stops at R-30, the number is an extrapolation: buy the next size up and keep the extra.
Bags per 1,000 sq ft
| R-value | Cellulose | Blown fiberglass | Settled depth (cellulose) |
|---|---|---|---|
| R-11 | 8.2 | — | 3.5 in |
| R-13 | 10.7 | 6.3 | 4.1 in |
| R-19 | 18.4 | 9.2 | 5.7 in |
| R-30 | 33.2 | 15.5 | 8.9 in |
What actually decides the depth
R is thickness divided by conductivity. Blow it too thin with the right bag count and you get the wrong R, because the machine was set to a heavier density. The chart assumes the machine is set correctly — ask the rental desk for the settings on the bag, not for a guess.
Working it out yourself
The bag chart on the product is the whole calculation. Four steps:
1. Net the area. Measure the attic floor between the joists and subtract the chimney, the hatch and any HVAC platform. A 1,000 sq ft house often has 850 sq ft of open attic.
2. Find the coverage. At R-38 a 25 lb bag of cellulose covers about 23 sq ft. The bag says so in a table, and brands differ by a few square feet.
3. Divide. 1,000 ÷ 23 = 43.5, so 44 bags. Round up — half a bag is not a thing.
4. Check the depth. R-38 cellulose settles to about 11 in. If the bag count says 44 and the ruler says 8 in, the machine is set too lean.
Cost is 44 × $14 = $616 in material. The blower is usually free with a 20-bag order.
What changes the number
What is already up there. Four inches of old fiberglass is roughly R-13. To reach R-38 you add about 7 in, not 11 — the bag chart assumes a bare attic.
Air leaks first. Blowing over open top plates and can lights wastes the R you just bought. Seal the big holes with foam and caulk before the hose comes out; it is the cheapest hour of the project.
Baffles. Every soffit vent needs a 1 in channel against the roof deck, or the first few inches of insulation block the intake. Baffles cost $2–$4 each and take a minute.
Climate. R-30 is the usual target in the South, R-38 through the middle, R-49 in the North. Going one step above code rarely pays back in a mild climate.
Density. The same 44 bags blown at the wrong setting can settle to 8 in or 13 in. Ask the rental desk for the bag's settings, and use the depth ruler as the final check, not the bag count.
What R-value to aim for
The target is set by climate, not by the calculator. The code table, condensed:
| Where you are | Attic target | Settled cellulose |
|---|---|---|
| Deep South (zones 1–2) | R-30 | 9 in |
| Middle (zones 3–4) | R-38 | 11 in |
| North (zones 5–6) | R-49 | 14 in |
| Far north (zone 7+) | R-60 | 17 in |
Going one step above the code number rarely pays back in a mild climate and usually does in a cold one. The depth column is cellulose; blown fiberglass needs about 15% more depth for the same R.
What it costs, installed
Material for 1,000 sq ft at R-38 is about $600 in cellulose or $500 in fiberglass. A pro install runs $1.50–$3.50 a sq ft in 2026, so the same attic is $1,500–$3,500 — material, machine, two people and the cleanup included.
DIY sits in the middle: bags, a free blower, a helper feeding the hopper, half a day. Two people are not optional — one in the attic with the hose, one at the machine is the whole job.
Add-ons change the total more than the insulation does: air sealing $500–$1,000, baffles a few dollars each, and removing old insulation $1–$2 a sq ft if it is wet or contaminated. None of those are in the $616 material number.
Frequently asked
How many bags of blown-in insulation for 1,000 sq ft?
At R-30, cellulose runs about 33 bags per 1,000 sq ft and fiberglass about 16. The bag count is set by the manufacturer's coverage chart, not by the bag weight.
What depth is R-38?
About 12 inches for cellulose and 13 inches for blown fiberglass once it settles. The bag chart and the depth chart have to agree — a thin attic with enough bags is still not R-38.
Should I remove the old insulation?
Not if it is dry and clean. Blow the new material over the top to reach the target depth. Remove it only if it is wet, compacted to half its depth, or contaminated by animals.
Does covering the soffit vents matter?
Yes. Baffles keep a 1 inch channel against the roof deck so the attic still vents. Blocked soffits turn into condensation and ice dams, which costs more than the insulation saves.